What to do if Omron Inverter shows OC (Overcurrent) error?
- SSydney SmithAug 20, 2025
If your Omron Inverter displays an OC (Overcurrent) error, the suggested solution is to reset the device after identifying what triggered the overcurrent.
What to do if Omron Inverter shows OC (Overcurrent) error?
If your Omron Inverter displays an OC (Overcurrent) error, the suggested solution is to reset the device after identifying what triggered the overcurrent.
How to fix OV (Overvoltage) on Omron Inverter?
If your Omron Inverter displays an OV (Overvoltage) error, you can try increasing the deceleration time or connecting an optional braking resistor.
Why is my Omron SYSDRIVE 3G3SV overheating (OH error)?
If your Omron Inverter displays an OH (Inverter Overheat) error, it could be due to several reasons: * The load might be too large. * The V/f characteristics might not be proper. * The setting time might be too short. * The ambient temperature might exceed 45°C. To resolve this, correct the load size, V/f set value, or ambient temperature accordingly.
What causes UV (Undervoltage) error on Omron Inverter?
If your Omron Inverter displays an UV (Undervoltage) error, it could be due to: * Reduced input power supply voltage. * Open phases. * Momentary power loss. Check the power supply voltage, ensure the main circuit power supply wiring is properly connected, and verify that the terminal screws are tightened well.
How to troubleshoot OL1 (Motor Overload) on Omron SYSDRIVE 3G3SV Inverter?
If your Omron Inverter displays an OL1 (Motor Overload) error, the suggested solution is to correct the load size, adjust the operation pattern, or modify the V/f set value. Also, ensure you set the rated current value as described on the motor nameplate.
What should I do if my Omron SYSDRIVE 3G3SV Inverter shows OL2 (Inverter Overload) error?
If your Omron Inverter displays an OL2 (Inverter Overload) error, the suggested solution is to correct the load size, adjust the operation pattern, or modify the V/f set value. Additionally, recheck the inverter capacity to ensure it is adequate for the application.
How to check for GF (Ground Fault) on Omron SYSDRIVE 3G3SV?
If your Omron Inverter displays a GF (Ground Fault) error, check that the motor or load side wiring is not grounded.
What to do if Omron SYSDRIVE 3G3SV displays CPF (Control Function Fault)?
If your Omron Inverter displays the error code CPF, turn off the power supply and then turn it back on. If the fault persists, the suggested solution is to replace the inverter.
How to fix CPF-01 (Transmission error or ROM fault) on Omron SYSDRIVE 3G3SV Inverter?
If your Omron Inverter displays the error code CPF-01 (Transmission error or ROM fault), turn off the power supply and then turn it back on. If the fault persists, the suggested solution is to replace the inverter.
What to do for CPF-05 (AD converter fault) on Omron Inverter?
If your Omron Inverter displays the error code CPF-05 (AD converter fault), turn off the power supply and then turn it back on. If the fault persists, the suggested solution is to replace the inverter.
Covers site selection and mounting requirements for optimal performance and lifespan.
Provides instructions for connecting power and control circuits to the inverter.
Details wiring for the primary power input and motor output terminals.
Explains connections for external control signals and communication.
Specifies requirements and methods for safely grounding the inverter unit.
Guides users on operating the inverter, including pre-operation checks and methods.
Describes the two primary methods for operating the inverter: external terminal and digital operator.
Covers initial parameter settings and configurations required before operating the inverter.
Explains how to interpret fault displays and troubleshoot common issues.
Lists potential causes for various fault displays and suggests corrective actions.
Lists the technical specifications, electrical characteristics, and performance data of the inverter.
Contains detailed electrical and performance specifications for different inverter models.
Illustrates the main circuit and control circuit wiring connections for the inverter.
Defines the function and description of each terminal on the inverter's main circuit.
Details the layout of the digital operator's display, buttons, and indicator lamps.
Guides users on navigating and setting various functions and constants via the digital operator.
Guides on monitoring various operational parameters like frequency, current, and fault status.
A comprehensive list of all available functions and constants with their initial settings.
Provides in-depth explanations for each function and constant parameter.
Lists and explains the various protection functions built into the inverter for safety.