EasyManuals Logo

Omron SYSMAC CJ1W-EIP21 User Manual

Omron SYSMAC CJ1W-EIP21
464 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #352 background imageLoading...
Page #352 background image
326
Using the Automatic Clock Adjustment Function Section 12-2
12-2-2 Settings Required for Automatic Clock Adjustment Function
The following settings must be set in the Unit Setup when using the automatic
clock adjustment function.
Note When the Server specification type field in Auto Adjust Time Tab is set to Host
name.
CX-
Programmer
tab
Settings Setting conditions Reference
Auto Adjust
Time
Server specification
type
Required. 12-2-3 Auto Adjust
Time on page 327
IP Address One or the other is
required, depending
on the Server specifi-
cation type setting.
Host name
Port No. Rarely required.
(Change when a set-
ting other than the
default setting of 123
is required.)
Get the time informa-
tion from the SNTP
server
Required.
Auto Adjust Time Optional
Retry timer Optional (Change
when the default set-
ting of 10 seconds is
unacceptable.)
Adjust Time Optional
DNS (See
note.)
IP Address Required. 3-8 TCP/IP and Link
Settings on page 52
Port No. Rarely required.
(Change when a set-
ting other than the
default setting of 53
is required.)
Retry timer Optional (Change
when the default set-
ting of 10 seconds is
unacceptable.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ1W-EIP21 and is the answer not in the manual?

Omron SYSMAC CJ1W-EIP21 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ1W-EIP21
CategoryNetwork Hardware
LanguageEnglish

Related product manuals