7.6 Disable the safety switch
If you want to disable the function of Safe SW., you can change the value of
O31 from “1” to “0” normally, in a particular case, for example, the Safe SW. broke
down, you can power on while press “C+” key to disable the function of Safe SW.
warning
it means potential security problems for you if you disable the function of Safe
SW., so attention please.
7.7 Parameter list
SN
PARAMETER
RANGE
DESCRIPTION
S Type Para
S01
Max Speed
500
3000spm
Unit: stitch/min
S02
Min Speed
150
500spm
Unit: stitch/min
S03
Start tacking speed
500
2000spm
Speed adjustment for
start tacking
S04
End tacking speed
500
2000spm
Speed adjustment for end
tacking
S05
Bar-tacking speed
500
2000spm
Speed adjustment for
bar-Tacking
S06
C-S sewing speed
500
2000spm
Speed adjustment for
constant-stitch sewing
S07
Trimming speed
150
300spm
Speed adjustment for
trimming
S08
Soft start speed
200
500spm
Soft start speed
S09
Speed limit for stroke
height level 1
500
4000spm
S10
Speed limit for stroke
height level 2
500
4000spm
S11
Speed limit for stroke
height level 3
5004
000spm
S12
Speed limit for stroke
height level 4
500
4000spm
T Type Para
T01
RVS action time
1200ms
Action time of the REV
SOL.
T02
RVS release time
1200ms
Release time of the REV
SOL.
T05
Foot lifter delay time
setting
1500ms
Foot lifter Delay time
adjustment for pedal’s
feet lift position
T06
Running-Delay time
setting
1500ms
Running delay time
adjustment for Automatic
Foot Lifter