141
Falcon+ Operator Manual
OPEX Corporation
MFD Skew Damage
Exceeded Sensor
Blocked
The MFD Skew Damage Exceeded Sensor is
blocked.
Out Of Bounds Sensor
Blocked
The Out Of Bounds Sensor is blocked.
Out of Bounds Detected A piece is too tall for the imager.
Justification Sensor
Blocked
The Justification Sensor is blocked.
Feed Singulation Defeat
Button Stuck
The override feed control button is stuck in a
down position.
Skew 9 Sensor Blocked The Skew 9 Sensor is blocked.
Skew 8 Sensor Blocked The Skew 8 Sensor is blocked.
Skew 7 Sensor Blocked The Skew 7 Sensor is blocked.
Skew 6 Sensor Blocked The Skew 6 Sensor is blocked.
Skew 5 Sensor Blocked The Skew 5 Sensor is blocked.
Skew 4 Sensor Blocked The Skew 4 Sensor is blocked.
Post Feed MFD Trail
Sensor Blocked
The Post Feed MFD Trail Sensor is blocked.
Stepper Stall Detected A Stepper Motor has stalled.
Pre Crush Roller Sensor
Blocked
The Pre Crush Roller Sensor is blocked.
Feed Entry RX Present
Sensor Blocked
The Feed Entry RX Present Sensor is blocked.
Fan Failure Detected A fan has stopped functioning.
Roller Bed Motor Fault
Detected
This event can occur during a job activation of
the roller bed motor and a stall, over-current,
under-current, thermal warning or thermal
shutdown is detected by the stepper controller.
Table 5: Reasons for jams (continued)

Table of Contents