Peel off one of the two
sealings along the
dotted line.
Fix bracket onto mounting plate with
supplied screws (M4x6,4pcs).
Place the bracket around the pole
and tighten firmly with pole locking
screws.
3-3.Pole Mount
An installation pole with an outside diameter of 43mm(1.66") must be used.
(Standard U.S.1
1
/
4
"pipe has an outside diameter of 1.66".)
For outdoor wiring, bury piping as
deep as possible. Some sites will
require metal coated cables for
underground wiring work.
Avoid aerial wiring
Wiring Sponge Pad
3-4.Electric Box Mount
For connections to single gang
electric boxes, follow instructions
for wall mounting.
Pitch 83.5mm (3.28")
3-5.Conduit Installation
Conduit can be installed directly into the bottom of the unit by
removing the knockout on the bottom on the cover.
Knockout
4.WIRING
VX-402REC
AUX INPUT:[NC]
VX-402
AUX INPUT:[NC]
Power wires should not exceed the following lengths.
VOICE CONTROL INPUT
POWER INPUT:9.5 - 18VDC
ALARM OUTPUT:[NC/NO] SELECTABLE
SPARE SPARE
TAMPER:[NC]
ALARM OUTPUT:[NC/NO] SELECTABLE
VOICE OUTPUT
POWER INPUT:9.5 - 18VDC
TAMPER:[NC]
JUMPER
JUMPER
-5-
Approx.
1m(33ft)
Approx.
10cm
(3.3")
Approx.
60cm(20")
IMPORTANT
Do not remove jumper while
slave is not connected. Otherwise,
VX-402 series continue to give the alarm.
Use AUX INPUT terminal only
when slave is used.
12V 14V 12V 14V
AWG 22(0.33m
áu
) 200m(670ft) 400m(1330ft) 110m(370ft) 230m(770ft)
AWG 20(0.52m
áu
) 340m(1130ft) 640m(2130ft) 180m(600ft) 360m(1200ft)
AWG 18(0.83m
áu
) 510m(1700ft) 1020m(3400ft) 290m(970ft) 570m(1900ft)
VX-402 VX-402REC
WIRE GAUGE
AWG 22(0.33mm
2
)
AWG 20(0.52mm
2
)
AWG 18(0.83mm
2
)