Selection of Zero Display Range
• The range is 0-6 with default set at 2. This selection doesn’t affect the
zero value but the indication
• In User Setting Mode, select “ZDSP?”
• The ashing number on the second line shows the present setting value
• Press [ZERO] or [TARE] to change the value
• Press [M+] to conrm the revised value or press [UNIT WEIGHT] to
cancel the revision and exit the function setting
Selection of Default Unit
• This setting is for choosing the default unit (kg, g, lb, oz) on startup
• In User Setting Mode, select “UNIT?”
• The ashing number on the second line shows the present unit setting
• Press [ZERO] or [TARE] to change the value
• Press [M+] to conrm the revised value or press [UNIT WEIGHT] to
cancel the revision and exit the function setting
Selection of Backlight
• There are three backlight options: ON, OFF & AUTO, the default is Auto
• In User Setting Mode, select “BLIG?”
• The ashing number on the second line shows the present setting
• Press [ZERO] or [TARE] to change the value
• Press [M+] to conrm the revised value or press [UNIT WEIGHT] to
cancel the revision and exit the function setting
Selection of Auto Calibration
• There are two modes for calibrating the unit weight automatically: ON &
OFF. The mode is set to OFF by default
• When the auto calibration is ON, the system can modify the difference
of counting automatically and the counting function will be more
accurate
• In User Setting Mode, select “ACAL?”
• The ashing number on the second line shows the present unit setting
• Press [ZERO] or [TARE] to change the value
• Press [M+] to conrm the revised value or press [UNIT WEIGHT] to
cancel the revision and exit the function setting