Version 1.0.1 - 2020-07-23 37Translation of original instruction
B20 | B25 | B32 EN
B20-B25-B32_GB.fm
5.3 Inspection and maintenance
The type and level of wear depends to a large extent on the individual usage and operating
conditions. Any indicated intervals therefore are only valid for the corresponding approved con-
ditions.
Interval Where? What? How?
Start of shift
After each
maintenance
or repair work
Drilling machine
Safety check on page 11
weekly
Clamping bolts
V-belt tension
Check if the attachment screws for the V-belt tension on the
left and right side of the drilling head are well fastened.
Check if the V-belts are well tightened. Checking the tension
of V-belts,
Speed variation on page 30.
Every month
Drill column and toothed rack
Oiling
Lubricate the drill column regularly with commercial oil.
Lubricate the toothed rod regularly with commercial grease
(e.g. friction bearing grease).
Img.5-1: B 20
Every 6
months
V-belts at the drill head
Visual inspection
Check whether the V-belts have become porous and worn.
Img.5-2: V-belt housing