Table 21-1 (Cont.) – Operating and Storage Temperatures for Current MICROS
Workstations
Device Operating Temperature Storage Temperature
PCWS 2015 and 2010 0°C (32°F) to 45°C (113°F),
90% relative humidity max
-25°C (-13°F) to 80°C (176°F)
KW270 Without Battery Pack:
-10°C(14°F) to 65°C (149°F)
90% relative humidity non
condensing at 65°C (149°F)
With Battery Pack:
Charging: 0°C (32°F) to 45°C
(113°F) Discharging: -10°C
(14°F) to 60°C (140°F)
Without Battery Pack:
-20°C (-4°F) to 80°C (176°F)
With Battery Pack
1
:
-5°C (23°F) to 30°C (86°F)
MICROS Tablet -10°C (14°F) to 60°C (140°F)
When Charging Battery:
0°C (32°F) to 45°C (113°F)
-25°C (-13°F) to 85°C (185°F)
Concessions Tablet (No
Battery)
-10°C (14°F) to 60°C (140°F) -25°C (-13°F) to 85°C (185°F)
MICROS Tabletw/ Base
Station
Without Battery Pack:
-10°C (14°F) to 60°C (140°F)
When Charging Tablet or
optional Base Station Battery
Pack:
0°C (32°F) to 45°C (113°F)
Without Battery Pack:
-25°C (-13°F) to 80°C (176°F)
With Battery Pack
1
:
-5°C (23°F) to 30°C (86°F)
Order Confirmation
Pedestal Remote Display
Unit
-35°C (-31°F) to 65°C (149°F) -35°C (-31°F) to 80°C (176°F)
1
See the Lithium Ion Battery Pack Storage Considerations section for more details
about storing batteries.
Lithium Ion Battery Pack Storage Considerations
The optional Lithium-Ion Totex Battery pack capacity degrades over time. The
mechanisms for capacity loss do not require the battery to be charged or discharged;
capacity loss can also occur during storage.
In general, capacity loss during storage can be minimized by removing the fully
charged battery pack from the equipment and storing it at the lowest possible
temperature for the shortest period of time. The storage environment must be low in
humidity and free of corrosive gases.
If the battery pack is fully charged, removed from the equipment, and stored at 20°C
(68°F) or less, then it should have maximum shelf life of six months. If the storage
temperature exceed 20°C (68°F) over a six month period, the shelf life is reduced and
we recommend that the battery pack be recharged every 30-60 days.
If storing the battery for less than 30 days, the ideal temperature is between
-10°C (-14°F) and 35°C (95°F)
Chapter 21
Lithium Ion Battery Pack Storage Considerations
21-3

Table of Contents

Other manuals for Oracle MICROS 700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle MICROS 700 Series and is the answer not in the manual?

Oracle MICROS 700 Series Specifications

General IconGeneral
BrandOracle
ModelMICROS 700 Series
CategoryTablet
LanguageEnglish

Related product manuals