EasyManua.ls Logo

Oracle Sun Fire X2270 M2 - Page 81

Oracle Sun Fire X2270 M2
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Name Color Activity
1 NET MGT 10/100
Ethernet LED
Green and
Amber
See Table 1
2,3,4 GigabitEthernet LED Green and
Amber
See Table 2
5 Server Locate LED White Use to identify a server in a rack. Activate locally by pressing the
Locate button or activate remotely using the ILOM.
O: Normal
On: Blinking
6 Server Service Action
Required LED
Amber The SP monitors the health of the system and activates the
Service Action Required LED.
O: Normal operation.
Slow blink: A new (unacknowledged) event that requires a
service action has been detected.
Steady on: An event has been acknowledged, but the
problem still requires attention.
The following conditions cause the SP to activate the Service
Action Required LED:
Voltage outside thresholds
Temperature above thresholds
Fan speed below thresholds (or not present)
24 correctable errors have occurred in a 24 hour period.
One correctable error has occurred.
7 Power OK LED Green Use to discern the power state of the server.
Steady On: Full-power mode on and OK.
Blinking: Standby power is on, but main power is o
Quick blink: in POST, diagnostics running
O: No power. AC cords not attached.
TABLE 1 10/100 Ethernet LED Activity Table
LED Name Color Activity
10/100 Ethernet
(right side)
Green On: Link established at 100 Megabits.
Amber On: Link established at 10 Megabits. Amber LED indicates that
the link established is not at full capacity for that port.
10/100 Ethernet
(left side)
Green On: Link Activity.
Rear Panel System Status LEDs