8 Inspection
47
8 Inspection
It is recommended to check the following four items after motor operation. If any
failure is found, stop the operation, and please contact your local sales office.
Inspection items
Check if abnormal noise is produced from the motor bearing section (ball
bearing).
Check if abnormal noise is produced from the gearhead bearing (ball bearing) and
gear meshing section.
Check if the motor cable is damaged or stressed. Also, check if the connections
with the driver are loosened.
Check if there is any misalignment between motor (gearhead) output and load
shafts.
Check if dust is deposited on the driver.
Note
Conduct the insulation resistance measurement or withstand voltage test
separately on the motor and the driver.