EasyManua.ls Logo

Orion OLMU-5520 - Network Configuration for MSCS; LAN Hub Connection Method; Network IP Address Settings

Orion OLMU-5520
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 30 - - 31 -
4.3.3. LAN Port For MLCD
4.3.3.1. In case of connection to a LAN Hub
This function is used to control the MLCD via LAN PORT.
* During the setting process, MLCD and control PC should be connected via RS-232C cable only. Do not
connect ethernet cable.
* After setting process, the control PC should be connected to one of MLCD sets with Ethernet cable only. For
the connection between the MLCD sets, they should be connected with RS-232C cables.
n Network IP setting for MLCD
1. Execute the MSCS.
2. Select Com Port and click the "Connect". Click the "Open New Design".
3. Turn on MLCD.
Click the right button of the mouse on the MLCD that you want to control on the screen configuration window.
(This MLCD should be connected to the LAN cable.)
4. Select "IP LAN
IP LAN Configurator or "Ctrl + L" to start Setup.
5. Type in the IP address from the network administrator.
6. Save the IP address by clicking
Set TCP/IP
after type-in.
7. Click "Get TCP/IP" and check whether the IP address is correct.