4.3. Communication Configuration
4.3.1. COM Port For MSCS
Com Port connects or disconnects the communication between PC and MLCD.
Connect MLCD to PC Com Port via RS-232C cable.
Go to MSCS Menu
Communication and set Com Port. Click 'Connect' using mouse or press 'Ctrl+C' using keyboard.
In order to disconnect communication, click 'Disconnect' using mouse or press 'Ctrl+D' using keyboard.
When you use USB-to-RS-232C converters, you need to set Com Port again, because MSCS uses
one of Com Port no. 1 to 30.
Available Com Port on the PC is automatically recognized and displayed.
Com Port Configuration
Baud Rate 115200bps(Fixed)
Data Bit 8Bits
Parity None
Stop Bit 1Bit
Flow Control None
4.3.2. LAN Port for MSCS
1. Execute the MSCS.
2. Select "Menu
Communication
Setup" or"Ctrl+U" to start setup.
3. Select "Socket" radio button.
4. Type in IP Address of MLCD.
5. Click "Ping Test" to check status of communication.
6. Close the Commnication setup window
• Menu Description
Serial
: Set the serial communication as a default communication.
Com Port
: Set the port of a PC to communicate with MLCD.
Baud Rate
: Fixed at 115200bps.
Caution: Users cannot change the Baud rate.
Socket
: Set the Ethernet LAN communication.
Edit Box
: Set the IP address.
Port Number
: Fixed as 9761.
Caution: Users cannot change the port number.
Ping Test
: Test the IP address.
Connect
: Connect the communication.
Communication Setup