Spectracom EPSILON CLOCK MODEL EC20S
17 User’s Manual
5.2 BACK PANEL DESCRIPTION
Connector
Type
Description
AC POWER
IEC 320 C14
AC power entry with integrated fuse.
DC POWER
XLR circular
DC power supply input.
1PPS J
n
50 Ω BNC
Distributed One Pulse Per Second outputs.
10MHz J
2n
50 Ω BNC
Distributed sinus frequency outputs.
‘EXT’ : External 1PPS
50 Ω BNC
External input for a 1PPS Synchronization source.
Ethernet 10/100 BaseT
50 Ω BNC
Network connectivity.
GPS Antenna
50 Ω N
Antenna inputs for GNSS receiver and remote
active antenna 5VDC supply.
ALARMS
SUBD-9
Dry contacts for alarms and RS232 input/output
for the Command Line Interface (CLI).
NMEA
SUBD-9
RS232 input/output for NMEA Time Of Day
messages.
GROUND
ØM4 lug stud
Casing grounding.