MAINTENANCE
7.3.1 CLEANING THE PLEXIGLAS LID
Wipe using a cloth made damp with water or a detergent specially meant for Plexiglas (maximum temperature 40°C).
Do not use other types of detergents.
Dry the lid thoroughly.
7.3.2 CLEANING THE SEALING BARS
CAUTION!
Burning hazard! Do not start cleaning operations when the sealing bars are hot.
Clean the upper part of the sealing bar using a damp cloth (water only).
7.3.3 CLEANING THE VACUUM CHAMBER
1) Switch the machine off by means of the ON/OFF main switch and disconnect the plug from the mains socket.
2) Lift the sealing bar by rotating it upwards (A - Fig. 1).
3) Extract the/two dater/s (B) to facilitate the following operations.
4) Take hold of the sealbag and pull it upwards (C - Fig. 2).
5) Insert the safety cap (D) in the central opening as shown in (Fig. 3).
6) Using a cloth soaked in detergent and/or a disinfectant solution, clean the bottom and sides of the vacuum chamber (Fig. 4); after cleaning, refit
the parts by repeating the above operations in reverse order.
7.3.4 DISINFECTING THE MACHINE
Switch the machine off by means of the ON/OFF main switch and disconnect the plug from the mains socket.
Spray the machine’s stainless steel surface with an alcohol-based disinfectant. Do not spray on the electrical parts or in the machine’s air vents.
Leave the disinfectant to act for a few minutes.
Wipe with a cloth soaked in clean water, then dry thoroughly with a clean cloth.
7.3.5 CLEANING THE DATER CONTACTS.
Remove the dater (E) from its seat on the appliance.
Clean the lower part of the contact (F) using a cloth dampened with a little alcohol.