51
PB
Press the <NEXT> soft key to view the Auto Restart
screen.
Pressing the fourth soft key selects among the three
FLEXmax 80 Auto ReStart modes: 0 (default), 1, and 2.
Auto ReStart allows the FLEXmax 80 to perform internal
recalibrations.
Mode 0Auto ReStart mode is disabled; the FLEXmax
80 recharges continuously from an available source
and never Restarts. Mode 0 would be chosen to avoid
spinning a microhydro generator every 1.5 hours.
Mode 1—once every 1.5 hours, when the FLEXmax 80
is in Bulk, it will briey Restart and initiate a full panel
tracking. This will not reset any counters or charging
stages or statistics.
Mode 2Auto ReStart every 1.5 hours; in Bulk, Absorb,
and Float modes, it will briey Restart and initiate a
full panel tracking. This will not reset any counters or
charging stages or statistics.
ADVANCED MENU
RTS Compensation
A 14.4 V F 13.8V
EXIT NEXT LIMIT SET
AUTO RESTART
ADVANCED MENU
Auto ReStart
MODE 2
EXIT NEXT MODE
ADVANCED MENU
Auto ReStart
MODE 0
EXIT NEXT MODE
ADVANCED MENU
Auto ReStart
MODE 1
EXIT NEXT MODE