EasyManua.ls Logo

Outback Power Systems FLEXMAX 80 - Wire Distance Chart Continued; Wire Distance for 48 V, 60 V, 72 V PV Arrays

Outback Power Systems FLEXMAX 80
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
PB
48V PV ARRAY (64v Vmp)
#8 #6 #4 #3 #2 #1/0 #2/0 #4/0
10 62 98 156 196 247 393 496 789
20 31 49 78 98 124 197 248 395
30 21 33 52 65 82 131 165 263
40 15 24 39 49 62 98 124 197
50 12 20 31 39 49 79 99 158
60 10 16 26 33 41 66 83 132
70 9 14 22 28 35 56 71 113
60V PV ARRAY (80v Vmp)
#8 #6 #4 #3 #2 #1/0 #2/0 #4/0
10 77 122 195 245 309 492 620 987
20 39 61 97 122 155 246 310 493
30 26 41 65 82 103 164 207 329
40 19 31 49 61 77 123 155 247
50 15 24 39 49 62 98 124 197
60 13 20 32 41 52 82 103 164
70 11 17 28 35 44 70 89 141
72V PV ARRAY (96v Vmp)
#8 #6 #4 #3 #2 #1/0 #2/0 #4/0
10 93 147 234 294 371 590 745 1184
20 46 73 117 147 186 295 372 592
30 31 49 78 98 124 197 248 395
40 23 37 58 73 93 148 186 296
50 19 29 47 59 74 118 149 237
60 15 24 39 49 62 98 124 197
70 13 21 33 42 53 84 106 169
WIRE GAUGE
AMPS
WIRE GAUGE
AMPS
WIRE GAUGE
AMPS
METRIC
#8…8.37mm
2
#6…13.30mm
2
#4…21.15mm
2
#3…26.7mm
2
#2…33.6mm
2
#1/0…53.5mm
2
#2/0…67.4mm
2
#4/0…107mm
2

Table of Contents