Safety equipment
Transport position monitoring system
The following systems are optionally available:
Main boom in horizontal position - maximum 0° (height warning) - legally required in Europe
(EN12999).
Monitoring of the manual outrigger beams (interlock) legally required in Europe (EN 12999).
Usually the installer connects all above mentioned systems to a warning light and buzzer, as well as
immobilizer, etc. in the driver's cab.
Emergency operation after remote control failure
Small handset (P4):
Remove the battery and insert the charged spare battery. Charge the battery you removed
immediately.
If the crane movements are still not possible even via radio remote control:
Caution!
In emergency operation mode all safety devices such as emergency
cut-off button, transport position monitoring and all load moment
restricting systems, etc. are ineffective.
Immediately reduce the load moment in emergency operation.
If you continue working you put yourself and others at risk of fatality.
Immediately end loading operations.
Caution!
Emergency operation may only be used to move the crane to the
transport position.
After this contact a PALFINGER partner immediately to get the crane
repaired.
If you continue working you put yourself and others at risk of fatality.
Immediately end loading operations.