Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
4
Location /
Installation
4 – 13
Location / Installing the device
Location
4 Location / Installing the device
4.1 Location
Weights of the compact units
Aquarea LT single-phase (one fan) 112 kg
Aquarea LT single-phase 153 kg
Aquarea LT three-phase 157 kg
Aquarea T-CAP single-phase 155 kg
Aquarea T-CAP three-phase 158 kg
Aquarea HT n. a.
The installation location must meet the following criteria:
General
Even and horizontal
Load-bearing (see device weight table)
No outside temperature under -20 °C
,QVWDOODWLRQDWDKHLJKWVXIÀFLHQWWRSURWHFWDJDLQVWZHDWKHULQÁXHQFHV
such as snow or water levels
The height difference of the liquid system circuit may not exceed 7 m
Easy access for maintenance work
Condensate must drain away easily
No damage to other objects if water leaks
If a solar installation is connected, the connection cable between
the solar pump station and the compact unit may not be longer than
10 metres
Minimum clearances
The minimum clearances (see Figure) must be observed.
Minimum clearances of the compact unit to adjacent walls and objects, indicating the air
ÁRZGLUHFWLRQ
1
Minimum clearance 100 mm
2
Minimum clearance 300 mm
3
Minimum clearance 1,000 mm
2
1
2
3