6 21Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
6
Hydraulic
installation
Hydraulic installation
³ Proceed as follows to install a condensate pipe to drain condensate
formed in the compact unit during operation:
³ Use a drain hose with an internal diameter of 15 mm.
³ Connect the drain hose to the compact unit.
³ Lay the drain hose with a downward slope. For long drain hoses,
use a metal support if necessary to prevent the hose bending.
³ Lay the drain hose so that closures or blockages cannot occur.
³ Do not insert the drain hose in a waste water system from which
aggressive gasses such as ammonia gas, sulphur gas etc. can
escape.
1
Connecting the drain hose
1
Warning!
If the device is used in areas
where the temperature can re-
main below zero for 2 to 3 days,
condensate pipes should not be
used
, as the condensate could
freeze, which can cause mal-
functions.