Loading...
11 – 58 Aquarea air/water heat pump – Installation manual for compact systems 03 / 2013
Appendix
Error codes
If an error occurs during operation, the system stops, the OFF/ON LED
ÁDVKHVDQGDQHUURUPHVVDJHLVVKRZQRQWKHGLVSOD\7KHHUURUFRGH
is stored in the EEPROM of the indoor unit.
Acknowledging the error code
³ Press and hold the ERROR RESET
(< 8 seconds), until you hear a beep.
Reading the last error code stored in the EEPROM
³ Press the CHECK button for 5 seconds to access Status mode.
³ Press the SEARCH UP or DOWN button to see the last error code.
³ Press the CANCEL button or wait 30 seconds to exit STATUS mode.
Deleting the last error code stored in the EEPROM
³ Press and hold the ERROR RESET
(> 8 seconds), until you hear a beep.
SET
SELECT
SETTING
OFF/ON
WATER OUTLET
TIMER OUTDOOR
ACTUAL
HEATER
SETTING
STATUS
SERVICE
DEFROST
HEAT
COOL
TANK
QUIET
HEATER
FORCE
BOOSTER
STATUS
SEARCH
CANCEL
CLOCK FORCE SERVICE
ERROR
RESET
OFF/ON QUIET HEATER
MODE CHECKTIMER
OPERATION
1
Display of system errors
2
CHECK button
3
SEARCH UP/ DOWN buttons
4
Error reset button
(ERROR RESET)
5
CANCEL button
1
2
3
45