Port
Sets the destination port number to forward the tracking data such
as Pan/Tilt/Zoom or other information via UDP.
The setting is confirmed with the [Set] button.
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554,
995, 10669, 10670, 59000 to 61000
Factory settings:
Client1: 1111
Client2: 1112
Client3: 1113
Client4: 1114
<NOTE>
• You cannot set up clients having a combination of two or more IP
addresses with duplicated ports.
P2 Cast connection setting screen [P2 Cast]
Sets whether to enable or disable connection to P2 Cast, as well as the
destination server URL and the user account.
The setting is confirmed with the [Set] button.
Mode [On, Off]
Sets whether to connect this unit to P2 Cast via a network.
Factory settings: Off
Cloud URL
Sets the server URL of P2 Cast to be connected when [Mode] is [On].
<NOTE>
• You can set the URL with maximum 512 characters.
User ID
Sets the user ID for connection to P2 Cast when [Mode] is [On].
Password
Sets the password for connection to P2 Cast when [Mode] is [On].
User management screen [User mng.]
The users and personal computers (IP addresses) that can access the
unit from personal computers and mobile terminals are registered in the
User management screen [User mng.].
The User management screen [User mng.] consists of [User auth.] and
[Host auth.].
User authentication screen [User auth.]
Click the [User auth.] of User management screen [User mng.].
Configure the user authentication settings for the personal computers
and mobile terminals that can access the unit.
Up to 9 users can be registered.
<NOTE>
• If user authentication fails more than 8 times within a 30-second period
from the same IP address (personal computer), access to the unit will
be disabled for a certain period.
z Setting status
The current user authentication settings and user authentication method
are displayed. The currently registered account information is also
displayed.
z Mode
User auth. [On, Off]
User authentication is set to [On] or [Off] here.
The setting is confirmed with the [Set] button.
Factory settings: Off
Authentication [Basic, Digest]
Specify the method of user authentication to use.
The setting is confirmed with the [Set] button.
Basic Use basic authentication.
Digest Use digest authentication.
Factory settings: Digest
124