54
13.4 Indoor Fan Speed Control
• Indoor fan speed can be set using remote control.
13.4.1 Fan Speed Rotation Chart
Fan Speed (rpm)
Speed
CS-C12MKF CS-C18MKF CS-C24MKF CS-C28MKF
Shi 1150 1430 1500 1530
Hi 1110 1280 1390 1490
Me 950 1180 1240 1400
HLo 840 1140 1190 1330
CLo 810 1080 1110 1250
Lo- 760 850 970 1050
SLo 740 670 750 830
Qhi 1040 1190 1300 1400
QMe 880 1090 1150 1310
QLo 740 990 1020 1160
13.4.2 Automatic Fan Speed Control
• When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the
table.
o Fan speed rotates in the range of Hi and Me (For CS-C12MK).
o Fan speed rotates in the range of Hi, Me and Lo- (For CS-C18MK, CS-C24MK and CS-C28MK).
o Deodorizing Control will be activated.
For CS-C12MK
SHi Hi Me HLo CLo Lo- SLo
Variable
rpm
Stop
Hi o
Me o
Manual
Lo o
Normal
Auto o o o o o
QHi
Hi-
70
QMe
Me-
70
Manual
QLo
CLo-
70
Quiet
Auto
Hi-
70
Me-
70
o o o
Manual o
Cooling
Powerful
Auto o
Manual o o
Normal
Auto o o
Manual o o
Quiet
Auto o o
Manual o o
Soft Dry
Powerful
Auto o o