11.2.4 Connect the Cable to the Indoor Unit
a) INDOOR POWER SUPPLY MODEL (1.0 ~
2.5HP)
Connecting cable between indoor unit and
outdoor unit shall be approved polychloroprene
sheathed 3 x 1.5 mm
2
(1.0 ~ 1.5HP) or 3 x 2.5mm
2
(2.0 ~ 2.5HP) flexible cord, type designation 245
IEC 57 or heavier cord. Do not use joint connection
cable. Replace the wire if the existing wire (from
concealed wiring, or otherwise) is too short.
Secure the connecting cable onto the control board with the holder.
This equipment must be properly earthed.