9.7.8. Time Delay Safe Control
The compressor will not start for three minutes after stop of operation.
9.7.9. Outdoor Fan Remaining Heat Removal Control
When compressor stops, outdoor fan operates at High speed for 1 minute to remove the remaining heat.
9.7.10. Crank Case Heater Control
Crank case heater ON when the compressor is shutdown and discharge temperature is 20°C to prevents the refrigerant solving
into compressor oil inside the compressor shell at cold condition.
9.7.11. Pump Down
To enable pump down operation, at outdoor PCB, set the DS1 to OFF position.