12.3 Outdoor Fan Motor Operation
Outdoor fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30
seconds after compressor stops operation.
30 s
Compressor
Outdoor Fan
ON
ON
OFF
OFF
ON
12.3.1 Vertical Airflow
Airflow Direction
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air
conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air
conditioner is stopped using remote control, the vane will shift to close position.
* Above angle data is for reference only.
12.3.2 Horizontal Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.3.3 Quiet operation
To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing
QUIET button on remote control.
Once Quiet mode is active, the unit will continuously operate in QUIET Mode until cancel the mode by pressing
QUIET button on remote control.
12.3.4 Powerful operation
To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or
stop by pressing POWERFUL button on remote control.
When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode
by pressing POWERFUL button on remote control. Operation details are as the fig. below.
1. For cooling, soft Dry mode
1 2 3 4 5
10° 21° 31° 40° 50°
Normal
Powerful
10° 21° 31° 40° 50°
Normal
Powerful
Normal 22° 35° 50° 60°
Powerful 3 40° 4 58° 68°
Normal
Powerful
,,36°
Manual
,,33°,45°(Beginning of POWERFUL mode)
10°-5
,35°(Beginning of POWERFUL mode)
12°
Operating Mode
Cooling
Soft dry
12°
Heating
Manual
Auto
Manual
Auto
Auto

Other manuals for Panasonic CS-RE9NKR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-RE9NKR and is the answer not in the manual?

Panasonic CS-RE9NKR Specifications

General IconGeneral
BrandPanasonic
ModelCS-RE9NKR
CategoryAir Conditioner
LanguageEnglish

Related product manuals