12
Model
Indoor CS-TZ35TKEW CS-TZ42TKEW
Outdoor CU-TZ35TKE CU-TZ42TKE
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.85 3.50 3.90 0.85 4.20 4.60
BTU/h 2900 11900 13300 2900 14300 15700
Kcal/h 730 3010 3350 730 3610 3960
Running Current A – 4.40 – – 5.60 –
Input Power W 255 1.00k 1.19k 265 1.26k 1.65k
Annual Consumption kWh – 500 – – 630 –
EER
W/W 3.33 3.50 3.28 3.21 3.33 2.79
BTU/hW 11.37 11.90 11.18 10.94 11.35 9.52
Kcal/hW 2.86 3.01 2.82 2.75 2.87 2.40
ErP
Pdesign kW 3.5 4.2
SEER (W/W) 6.2 5.8
Annual
Consumption
kWh 198 253
Class A++ A+
Power Factor % – 99 – – 98 –
Indoor Noise (H / L / QLo)
dB-A 42 / 30 / 20 44 / 31 / 29
Power Level dB 58 / 46 / 36 60 / 47 / 45
Outdoor Noise (H / L)
dB-A 48 / – 49 / –
Power Level dB 63 / – 64 / –
Heating
Capacity
kW 0.80 4.00 5.10 0.80 5.00 6.80
BTU/h 2730 13600 17400 2730 17100 23200
Kcal/h 690 3440 4390 690 4300 5850
Running Current A – 4.60 – – 6.00 –
Input Power W 200 1.05k 1.42k 200 1.35k 2.05k
COP
W/W 4.00 3.81 3.59 4.00 3.70 3.32
BTU/hW 13.65 12.95 12.25 13.65 12.67 11.32
Kcal/hW 3.45 3.28 3.09 3.45 3.19 2.85
ErP
Pdesign kW 2.8 3.6
Tbivalent °C -10 -10
SCOP (W/W) 4.2 3.8
Annual
Consumption
kWh 933 1326
Class A+ A
Power Factor % – 99 – – 98 –
Indoor Noise (H / L / QLo)
dB-A 42 / 33 / 22 44 / 35 / 28
Power Level dB 58 / 49 / 38 60 / 51 / 44
Outdoor Noise (H / L)
dB-A 50 / – 51 / –
Power Level dB 65 / – 66 / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 3.70 / 1.26k / 2.94 4.93 / 1.81k / 2.72
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.30 / 1.35k / 2.44 3.90 / 1.70k / 2.29
Max Current (A) / Max Input Power (W) 6.3 / 1.42k 9.0 / 2.05k
Starting Current (A) 4.60 6.00
www.ampair.co.uk | sales@ampair.co.uk