Heating Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overheating.
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
The setting temperature will be decrease by
2
°C at the start
of operation and by
3
°C one hour later.
The fan speed refer to Indoor Fan Motor Control.
Sleep Mode operation time is
8
hours, the operation will be
stop after
8
hour.
When used together with the Timer, the Timer has priority.
7.6. Random Auto Restart Control
If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the
power is resumed. It will start with previous operation mode and airflow direction.
Restart time is decided randomly using 4 parameter:
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
Random Auto Restart Control is not available when Timer is set.
This control can be omitted by open the circuit of JX5. (Refer Circuit Diagram)
7.7. Delay ON Timer Control
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
For Heating mode, the operation will start 30 minutes before the set time.
For Automatic mode, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
7.8. Remote Control Signal Receiving Sound
Long beep sound will be heard when:-
Stopping the Air Conditioner using ON/OFF switch.
Short beep sound will be heard for others.
To switch off the beep sound:-
Press the Automatic Operation Button continuously for 10 seconds or more (beep”“beep will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the Automatic Operation Button has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
32
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5

Other manuals for Panasonic CS-V12CTP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-V12CTP and is the answer not in the manual?

Panasonic CS-V12CTP Specifications

General IconGeneral
BrandPanasonic
ModelCS-V12CTP
CategoryAir Conditioner
LanguageEnglish

Related product manuals