18
Indoor
Model CS-Z71TKEA
POS (EAN) 5025232873371
Outdoor
Model CU-Z71TKEA
POS (EAN) 5025232873401
Dimension Unit
Height
(I/D / O/D)
mm (inch) 302 (11-29/32) / 695 (27-3/8)
Width
(I/D / O/D)
mm (inch) 1120 (44-1/8) / 875 (34-15/32)
Depth
(I/D / O/D)
mm (inch) 236 (9-5/16) / 320 (12-5/8)
Weight Net (I/D / O/D) kg (lb) 13 (29) / 49 (108)
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 15.88 (5/8)
Standard Length m (ft) 5.0 (16.4)
Length Range (min – max) m (ft) 3 (9.8) ~ 30 (98.4)
I/D & O/D Height Different m (ft) 20.0 (65.6)
Additional Gas Amount g/m (oz/ft) 25 (0.3)
Length for Additional Gas m (ft) 10 (32.8)
Drain Hose
Inner Diameter mm 16.7
Length mm 650
Indoor
Heat
Exchanger
Fin Material Aluminium (Pre Coat)
Fin Type Slit Fin
Row × Stage × FPI 2 × 17 × 21
Size (W × H × L) mm 836.5 × 357 × 25.4
Outdoor
Heat
Exchanger
Fin Material Aluminium
Fin Type Corrugated Fin (Pre Coat)
Row × Stage × FPI 2 × 31 × 19
Size (W × H × L) mm 36.4 × 651 × 904.5:874.5
Air Filter
Material Polypropelene
Type One-touch
Power Supply Indoor
Power Supply Cord Nil
Thermostat Electronic Contol
Protection Device Electronic Contol
Dry Bulb Wet Bulb
Indoor Operation
Range
Cooling
Maximum °C (°F) 32 (89.6) 23 (73.4)
Minimum °C (°F) 16 (60.8) 11 (51.8)
Heating
Maximum °C (°F) 30 (86.0) –
Minimum °C (°F) 16 (60.8) –
Outdoor Operation
Range
Cooling
Maximum °C (°F) 43 (109.4) 26 (78.8)
Minimum °C (°F) -20 (-40) –
Heating
Maximum °C (°F) 24 (75.2) 18 (64.4)
Minimum °C (°F) -15 (5.0) –
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C DRY BULB (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F
Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor 2/1°C.
4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature 20°C, outdoor -7/-8°C.
5. Standby power consumption ≤10.0w (when switched OFF by remote control, except under self protection control).