4 “1” will be blinking, press
SELECT
to set programme 1.
5 Press TIMER
OFF/ON
to select ON or OFF timer.
6 Press TIMER
UP
or
DOWN
to select your desired time.
If you want to set the timer together with your desired temperature, press
TEMP
to select the temperature.
7 Press
SET
to confirm programme 1. The selected day will be highlighted with .
o After 2 seconds, the display will move to the next programme. Repeat steps 4 to 7 to set programmes 2
to 6.
o During timer setup, if no button is pressed within 30 seconds, or if the
SET
button is pressed, the setting at
that moment is confirmed and timer setup is ended.
14.10 Auto Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
This type of control is not applicable during ON/OFF Timer setting.
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
14.11 Indication Panel
LED POWER TIMER QUIET POWERFUL
Color White White White White
Light ON Operation ON Timer Setting ON QUIET ON POWERFUL ON
Light OFF Operation OFF Timer Setting OFF QUIET OFF POWERFUL OFF
Note:
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
If Timer LED is blinking, there is an abnormality operation occurs.