42
7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor
unit according to the diagram below.
321tinu roodtuo eht no slanimreT
Colour of wires (connection cable)
Terminals on the indoor unit
LN123
(Power supply cord)
Terminals on the isolating
devices (Disconnecting means)
(L) (N)
Connection cable
Power
supply
cord
Terminal Board
Control
Board
Earth Wire
longer than
others AC
wires for
safety reason
Earth Wire
longer
than
others
AC wires
for safety
reason
Holder
Holder
Indoor & outdoor
connection cable
Power supply
cord
Outdoor unit
Isolating Devices
Tape
Tape
Recommended
length (mm)
Recommended
length (mm)
a bcdefg
55 35 35 50 40 35 60
WARNING
This equipment must be properly earthed.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.