12.2 Outdoor Unit
12.2.1 Select the Best Location
If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
Do not place any obstacles which may cause a
short circuit of the discharged air.
If piping length is over the [piping length for
additional gas], additional refrigerant should be
added as shown in the table.
Example: For Z25****
If the unit is installed at 10 m distance, the quantity of
additional refrigerant should be 25 g .... (10-7.5) m x
10 g/m = 25 g.
A
min
= (M / (2.5 x (LFL)
(5/4)
x h
0
))
2
A
min
= Required minimum room area, in m
2
M = Refrigerant charge amount in appliance, in kg
LFL = Lower flammable limit (0.306 kg/m
3
)
12.2.1.1 Outdoor Installation Diagram
h
0
= Installation height of the appliance : (2.2m for mini cassette & ducted is standard reference installed height)
(2.5m for mini cassette & ducted is minimum installed height given by
manufacturer)
(0.6m for floor console)
12.2.2 Install the Outdoor Unit
After selecting the best location, start installation
according to Indoor/Outdoor Unit Installation
Diagram.
1 Fix the unit on concrete or rigid frame firmly
and horizontally by bolt nut (ø10 mm).
2 When installing at roof, please consider strong
wind and earthquake.
Please fasten the installation stand firmly with
bolt or nails.
Model A B C D
Z25**** 570 mm 105 mm 18.5 mm 320 mm
Z35**** 540 mm 160 mm 18.5 mm 330 mm
Z50****
613 mm 131 mm 24 mm 360.5 mm
Z60****
Model
Horse
Power
(HP)
Piping size
Std.
Length
a
(m)
Max.
Elevation
b
(m)
Min.
Piping
Length
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Piping
Length for
add. gas
(m)
Indoor
A
min
(m²)
Indoor
A
min
(m²)
Indoor
A
min
(m²)
2.2m
for mini
cassette
2.5m
for mini
cassette
2.2m for
ducted
2.5m for
ducted
0.6m for
floorr console
Gas Liquid
Z25****
1.0HP
9.52mm
(3/8")
6.35mm
(1/4")
5
15 3 20 10 7.5 0.70 0.54 0.70 0.54 9.37
Z35****
1.5HP
15 3 20 10 7.5 0.77 0.59 0.77 0.59 10.29
Z50****
2.0HP
12.7mm
(1/2")
20 3 30 15 7.5 1.32 1.02 1.32 1.02 17.73
Z60****
2.25HP
20 3 30 15 7.5 1.45 1.12 1.45 1.12 N/A
This illustration is for explanation purposes only.
It is advisable to avoid more
than 2 blockage directions.
For better ventilation &
multiple-outdoor installation,
please consult authorized
dealer/specialist.
Installation parts you
should purchase (
)
Additional d rain
hose (
)
1/4" Liquid side
piping (
)
Gas side
piping (
)
Connection
cable (
)
Power supply
cable (
)
1
0
0
m
m
o
r
m
o
r
e
1
0
0
m
m
o
r
m
o
r
e
1
0
0
0
m
m
o
r
m
o
r
e
3
0
0
m
m
o
r
m
o
r
e
AB
C
D

Table of Contents

Other manuals for Panasonic CS-Z25UFRAW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-Z25UFRAW and is the answer not in the manual?

Panasonic CS-Z25UFRAW Specifications

General IconGeneral
BrandPanasonic
ModelCS-Z25UFRAW
CategoryAir Conditioner
LanguageEnglish

Related product manuals