EasyManua.ls Logo

Panasonic CU-MC140KE - Liquid Side Valve; Gas Side Valve

Panasonic CU-MC140KE
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 29 –
MAC9702008C2
CS-MC90KE
3-way Valve
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
Open
(With valve cap)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Service Port
Closed
(With cap)
Open
(Connected manifold
gauge w/charging
cylinder)
Closed
(With cap)
Closed
(With cap)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Service Port
Closed
(With cap)
Open
(Push-pin)
Closed
(With cap)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Open
(Connected manifold
gauge)
Works
Shipping
Evacuation
Installation and
Re-installation
Operation
Pumping down
(Transferring)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
Shaft Position
Closed
(With valve cap)
Closed
(Clockwise)
Open
(With valve cap)
Closed
(Clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
Open
(Counter-clockwise)
3-way Valve (Liquid Side)
3-way Valve (Gas Side)
Hexagonal wrench (4 mm)
Flare nut
To
piping
connection
To outdoor unit
Service
port cap
Service port
Pin
To outdoor unit
Valve cap
Service
port cap
Service port
Pin
To
piping
connection
Flare nut
Open position
Closed position
Open position
Closed position
Untitled-26 6/25/00, 5:33 PM29