Confirming the Unit Settings and Design ContentsFP2 Serial Data Unit
3 9
3.2 Setting the Transmission Speed and Transmission Format
Explanation of the bits
If the power supply is turned on with the factory settings still in effect, the status of the
bits in the transmission format address section (COM.1 1003 and COM.2 1004) in the
shared memory is as follows: 0000 0001 0001 1010 = H011A.
Bit status with the factory settings
87654321015 14 13 12 11 10 9
Bit No.
Setting contents
00000000000 11101
BCD H code
011A
To set the control signals CS and CD valid from the factory setting state, first turn bit 7
on, and then set the bit status to 0000 0001 1001 1010. This writes “H 019A” in the
program above to the shared memory.
Bit status when control signals CS and CD are valid
Start code
End code
Parity check
Control signals CS and CD
Stop bit
Data length
Transmission speed
87654321015 14 13 12 11 10 9
Bit No.
Setting contents
00000000000 11111
BCD H code
019A