6-5 
6.1.4 Interface Specifications (GT01)  
Interface for connecting PLC/External devices 
- COM port 
AIGT0030B1/AIGT0030H1 
AIGT0030B/AIGT0030H 
 AIGT0130B1/AIGT0130H1 
AIGT0130B/AIGT0130H 
AIGT0230B1/AIGT0230H1 
AIGT0230B/AIG0230H 
AIGT0032B1 
AIGT0032H1 
AIGT0132B1 
AIGT0132H1 
AIGT0232B1 
AIGT0232H1 
AIGT0032B 
AIGT0032H 
AIGT0132B 
AIGT0132H 
AIGT0232B 
AIGT0232H 
Conforms to RS232C  
(Non insulation type) 
Conforms to RS422  
(Non insulation type) 
Communication 
condition with 
external devices 
9600, 19200, 38400, 57600, 115200 bps 
Transmission distance  
(Total length) 
Max. 15 m  
(Baud rate: 19,200 bit/s) 
Max. 30 m 
(Baud rate: 
115,200 bit/s) 
Max. 500 m 
(Baud rate: 
115,200 bit/s) 
- MEWTOCOL (Protocol for PANASONIC PLC: FP series) 
- General-purpose serial (PANASONIC dedicated protocol) 
- Other companies’ PLC protocols (For the details, refer to the 
latest GTWIN HELP.) 
Connector terminal base (8-pin) 
Note1) 2) 3)
 
Note1) The (+) and (-) terminals are the power supply terminals for driving the main unit. 
Note2) Regarding power supply voltage, please pay due consideration to the cable length so that the 
applied voltage is within the operation voltage range. 
Note3) When supplying power from a power supply separate from the PLC, make sure the power cable 
is no longer than 10 m. (5 V DC type only) 
 
 
Interface for transferring screen data 
- TOOL port 
Conforms to RS232C (Non insulation type) 
Conditions for 
communications 
with GTWIN 
9600, 19200, 115200, 230400 bps 
Note1) 2)
 
Note1) The baud rate of 230400 bps is available when the USB/RS232C conversion cable is used. 
Note2) When the baud rate is set to 230400 bps, the connection using the GTWIN automatic 
communication setting function is not possible. Set the GTWIN communication setting to 230400 
bps, and then transfer data.