6-18
6.5 GT05
6.5.1 General Specifications
3.6 W or less (150 mA or less)
2.4 W or less (100 mA or less)
Insulation method of
power supply part
20 to 85% RH (at 25 C), non-condensing
10 to 85% RH (at 25 C), non-condensing
Between [power supply terminals] and [case]
500 V AC for 1 minute, Cutoff current 10mA (at default setting)
Insulation resistance
Note1)
Between [power supply terminals] and [case]
100 M or more, 500 V DC, measured with megohmmeter (at default
setting)
10 to 55 Hz (1-minute cycle)
Amplitude: 0.75 mm, 10 min on 3 axes
98 m/s
2
or more, 4 times on 3 axes
EN61131-2 (EMC Directive)
1000 V [P-P] or more, Pulse width 50 ns, 1s between power supply
terminals (based on in-house measurements)
Note2)
IP65 (Initial value, evaluated by us)
Dustproof and drip-proof from front panel only (packing used on panel
contact surface)
Note3)
Note1) Not isolated between the USB port, COM. port and the internal digital circuit.
Note2) When using our exclusive cable.
Note3) When reattaching, replace waterproof packing.