Chapter 4 Communications Control
4-10
4
Normal response data
Reading the present measurement value for sensor 03.
Request communication data
Normal response data
Data Setting/Operation Instruction Command
Request communication data
Normal response data
Setting +5.5 [mm] as displacement judgment threshold a for sensor 04.
Request communication data
Ex
Ex
% $ R
±
Sender no. Command
BCC
CR
9 5 0 0 0
Data block: 1-character symbol +
7-character integral part (no zero suppress)
BCC
% $ W
CR
Sender no. Command
% # W
±
Destination no. Command
BCC
CR
9 5 0 0 0
Data block: 1-character symbol +
7-character integral part (no zero suppress)
00
00
% 0 3 $ R M D
-
CR
**0 1 2 3 4
Measured value: -12.3456 [mm]
% 0 3 # R M D
CR
*
*
65
% 0 4 # W H A
+
CR
**0 0 5 5 0 00