Chapter 3 Function
3-20
3
Offset
A desired setting value can be added to/subtracted from the measurement value.
Measurement judgment will be possible from an offset in combination wit
h
“displacement judgment by setting the size of the master workpiece
(reference measurement object) for the offset, measuring the maste
r
workpiece, and turning the “zero set” ON.
Setting range Function
Initial value
-95000 to
+95000
-Set an offset in a range from 95000
to +95000.
(The decimal point position varies
with each model.)
Set "Offset" and turn "Zero Set" ON to make the setting value an offset value.
The display limit of the measurement value is ±95000. Make sure that the setting
value does not exceed the display limit.
Setting Procedure
1
Display the "Data Processing Setting"
screen while the system is in setting mode.
2
Press the [ENTER] key. The "Average
Time" screen will be displayed.
3
Press the [DOWN] key three times. The
"Offset" screen will be displayed.
4
Press the [ENTER] key. The present
offset value will be displayed. The
leftmost digit will be selected.
5
Press the [UP]/[DOWN] keys together to
change the selected digit.
6
Press the [UP]/[DOWN] key to change
the value of the selected digit or its sign.
(Example: Changing the value to
+2.500 [mm].)
7
Press the [ENTER] key and determine
the offset value.