Chapter 3 Function
3-24
3
Displacement Judgment
This function is used to set an upper limit (threshold a), lower limit (threshold
b), and hysteresis for the judgment of measurement values.
Item Panel display
Setting range Function
Threshold a -95000 to +95000
Threshold b -95000 to +95000
Hysteresis 0 to +95000
Sets threshold a,
threshold b and
hysteresis.
Supplemental remarks
The following default values apply.
Diffuse reflection Specular reflection
Type
Threshold
a
Threshold
b
Hystere
sis
Threshold
a
Threshold
b
Hystere
sis
30 mm +4mm -4mm 8μm +2mm -2mm 8μm
50 mm +10mm -10mm 20μm +5mm -5mm 20μm
85 mm +20mm -20mm 40μm +10mm -10mm 40μm
120 mm +60mm -60mm 120μm - - -
250 mm +150mm -150mm 300μm - - -
•
Make settings so that threshold a is larger than threshold b. The sensor head will
perform automatic discrimination, however, if the opposite settings are made.
•
The decimal point position varies with each model.
● Setting Procedure
(
Setting Threshold a
)
1
Display the "Output Setting" screen
while the system is in setting mode.
2
Press the [ENTER] key. The "Judgment
Output Selection" screen will be displayed.
3
Press the [DOWN] key once. The
"Threshold a" screen will be displayed.
4
Press the [ENTER] key. The present
threshold will be displayed. The leftmost
digit will be selected.
5
Press the [UP]/[DOWN] keys together to
change the selected digit.
6
Press the [UP]/[DOWN] key to change
the selected digit or its sign. (Example:
Changing the value to +5 [mm].)
7
Press the [ENTER] key to determine the
threshold.