Chapter 3 Function
3-13
3
3-3-3 Sensing Setting
Sampling Cycle
This function is used to make measurement cycle settings.
When measuring an object with poor received light intensity, such as blac
k
rubber, extend the sampling cycle to get sufficient light to perform stable
measurement.
Cycle Frequency Panel display
Meas.
object
200 μs
5 kHz
500 μs
2 kHz
1 ms
1 kHz
2 ms
500 Hz
*1 The measurement range may become narrow depending on measurement
object type.
*2 indicates the default value.
Setting Procedure
1
Display the "Sensing Setting" screen
while the system is in setting mode.
2
Press the [ENTER] key. The
"Sampling Cycle" screen will be
displayed.
3
Press the [ENTER] key. The present
sampling cycle will be displayed.
4
Press the [UP]/[DOWN] key to make
sampling cycle changes. (Example:
Changing the sampling cycle to 1 ms.)
5
Press the [ENTER] key to determine
the sampling cycle.
Brigh
t
Brightness of meas. object
Dark