4.1 Troubleshooting
Installation Manual 225
4.1.5 Troubleshooting by Error Log
When a major system error occurs in the Hybrid IP-PBX, the ALARM indicator on the front of the Basic Shelf
turns on red, and the system logs the error information.
Error Log Display Format
Below is the display format of the error log. For information about how to view the error log using the KX-
TDA600 Maintenance Console, refer to "2.5.8 Utility—Error Log" in the PC Programming Manual.
Example: KX-TDA600 Maintenance Console
Example: Station Message Detail Recording (SMDR)
Description
Item Description
1 Date The date of the error detection.
2 Time The time of the error detection.
3 Level Minor (MN ALM) Displays minor errors, which affect only a certain part of system
operation.
Major (MJ ALM) Displays major errors, which affect operation of the whole
system, or result in system failure.
4 Error Code The 3-digit error code assigned by the Hybrid IP-PBX.
12456
3 7
04/01/01 10:37AM MJ ALM #000 10000 MPR WDT overflow
04/01/01 11:07AM MN ALM #010 10000 AC power down
04/01/01 03:55PM MN ALM #301 10501 Digital trunk RAI reception
12 345 6

Table of Contents

Other manuals for Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports and is the answer not in the manual?

Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports Specifications

General IconGeneral
BrandPanasonic
ModelKX-TDA600 - Hybrid IP PBX Control Unit Max. 1008 Ports
CategoryPBX
LanguageEnglish

Related product manuals