Marking trigger : MRK
Inputs marking trigger (laser radiation startup trigger).
• Setting of marking trigger
STX MRK S
[Marking trigger]
1-byte
(Check sum) Delimiter
Name
Data
length
[byte]
Description Remarks
Marking trigger 1
“0”: stop
(available only with
“equidistant” status)
“1”: start
• Marking operation is started when this command
is accepted.
• During “equidistant” status at marking to ying
object, the instruction of marking start/stop is
executed.
Reference
• Marking is performed at command reception, regardless of the setting in “marking trigger” when “equidistant marking” is
set at the trigger type.
• When this command is sent when the marking trigger cannot be accepted (Ready is OFF), abnormal receiving response
is returned from laser marker.
⿎
Guide laser control : GID
Controls radiation of red guide laser for marking position conrmation.
• Setting of guide laser control
STX GID S
[Display contents]
1-byte
(Check sum) Delimiter
Name
Data
length
[byte]
Description Remarks
Display contents 1
“0”: Display stop
“1”: Marking area
“2”: Marking character
“3”: Dual pointer
Reference
• This command that controls the red guide laser become unavailable when DIP switch (No. 2) on the back of the
controller is turned OFF.
• This command can be transmitted only when the shutter is closed or when the “command reception mode ON” is set by
Command reception permission (MKM) command.