Lot character string : LTS
Sets the character string used for “Lot Function” to change characters depending on date/time and counter values.
• Setting / Readout data of lot character string
STX LTS
Sub
command
[Lot No.] [Period unit] [Start period]
[End period] [Marking character string]
Max. 33-byte
(Check sum) Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of lot character string
STX LTS R
[Lot No.] [Period unit]
3-byte
(Check sum) Delimiter
Name
Data length
[byte]
Description Remarks
Lot No. 1 “0”–“7” “4”–“7”: common lot
Period unit 2
Period condition Setting range
Year, week-
based year
“01”–“60”
Month “01”–“12”
Day “01”–“31”
Y/M “01”–“60”
M/D “01”–“60”
Hour “01”–“24”
Minute “01”–“60”
Hour/Minute “01”–“60”
Week “01”–“54”
Day of Week “01”–“07”
Counter “01”–“60”
The setting range varies depending
on the condition of period unit.
Start period 6
Period condition Setting range
Year, week-
based year
“198000”–“209900”
Month “000001”–“000012”
Day “000001”–“000031”
Y/M “198001”–“209912”
M/D “000101”–“001231”
(The higher 4 characters:
month, the lower 2
characters: date)
Hour “000000”–“000023”
Minute “000000”–“000059”
Hour/Minute “000000”–“002359”
Week “000000”–“000054”
Day of Week “000000”–“000006”
(“000000”: Sunday,
“000006”: Saturday)
Counter “000000”–“999999”
The start / end period of marking the
character string for setting is set.
The setting range varies depending on
the condition of period unit.
Set “??????” for both of start and end
period to delete it.
“??????” is indicated if the period
which has not been set is read out.
End period 6
Marking
character
string
Max. 18
Use the shift-JIS code.
(Up to 9 characters)
The character string to be marked with
the specied period is set. Specify
0-byte of data length to delete the
character string of period.
ME-LP400V-EX-6