- Eng-33 -
To Cook Food Using Sensor Reheat
Considering IR sensor positioned on the upper head of the side wall, if it fails to detect the surface temperature of the foods or
liquids themselves, in that way the detected temperature will go contradict with the actual temperature. Therefore, we do not
recommend using straight-sided containers with narrow necks when reheating a spot of food or liquids, in that the side wall of
the container will obstruct the infrared rays to get through and lead to error detection. In order to achieve superb performance,
the following steps should be taken:
1. When reheating solid foods, please use open, at container with food weight no less than 100 g.
2. When reheating liquids, avoid using straight-sided containers with narrow necks, and liquids under 200 ml.
IR sensor detects
the food temperature
rightly.
IR sensor may fails
to detect the food
temperature, in that the
side wall of the container
obstruct the infrared ray
given out by the food.
3. The default setting is 70 °C when plugging in. From the second time, the default setting will be changed to previously
setting if between 55~75 °C.
4. "
" will be displayed if food temperature measured is higher than selected temperature.
5. After reheating, stir then serve.
6. Please place the container at the center of the ceramic plate.
7. The plastic wrap should cover the food tightly, otherwise, the temperature of food may not be tested. If the plastic wrap is
overlapped, make sure the overlapped area is placed downwards.
Plastic lm
Food
8. Food less than 100 g can not be detected. It may cause overcook.
9. If the temperature of the cavity is too high, sensor reheat feature can not be used. Display window will appear "
".
Sensor reheat feature can be used again until the "
" disappear.
10. The actual temperature maybe different from the required temperature. It depends on the cavity temperature, the food
density, the container, the placement of the food etc.
11. Avoid using straight-sided containers with narrow necks when using Sensor Reheat.
Sensor Reheat feature is utilizing the IR sensor equipped within the cavity to detect surface temperature of the food in the MWO
to balance the reheating temperature and timing. This feature can cook food without setting power and time, only according to
the temperature as your require. The eld is -10~90°C. The recommended weight is 100-500 g.
1
Press Once.
Press once. " " symbol and "1" will appears in the display.
2
Select Desired Temperature.
Set the required temperature by using the dial.
3
Press .
Press once. The temperature you set will display. After detecting for a period of time, press Reheat pad
and the approximate current temperature will appear in the display window for 3 seconds.
(unnecessary step)
F0003BU00QP_Eng_04_160622.indd 33 2016/6/23 11:22:37