58
12. Tie the tray and thermal fuse to the evaporator with cable
tie.
13. Re-seal the defrost sensor and tie with the cable tie.
14. Place the new Evaporator Assy. to its place, when fixing
the Evaporator Assy. press it horizontally otherwise you
might damage the fixing plastics.
15. Weld the pipes with oxygen welding.
Note: You need to protect the plastic cabinet from the
fire of welding with a protector as shown in the below
pictures.