10 Service Mode
10.1. SERVICE CONTROL FUNCTION
You can check sensor temperature and comp. frequency during service function. Please refer to a service function section.During
the service function, damper thermostat is forcibly closed, and all fan motor is forcible operate except defrosting condition.
1. Sensor temperature of each compartment and out put signal of microcomputer.
Name of each compartment, sensor temperature, and output signal of microcomputer indicates on LED repeatedly.
• FC-Freezer compartment
• PC-Refrigerator compartment
• SC-Selectable compartment
• dC-Defrost sensor
• IC-Ice compartment
• AC-Ambient temperature
• C-Compressor speed
• Cd-Comp. integrated time(hh→mm)
Reset when defrosting
2. Compressor speed
"C"→ "--" means compressor stop condition.
3. Exception of indicates
-41 °C or below(PC,SC,IC,FC,DEF. sensor) → "LL"
+41°C or above(PC,SC,IC,FC,DEF. sensor) → "HH"
0°C or below(AT sensor) → "1"°C
+50°C or above(AT sensor) → "50"°C
(Caution)
Indicated temperature is sensor's temperature.
These temperatures are different from temperature of
foods.
DISPLAY C24 C35 C42 C58 C69 C80
SPEED (r/m) 1440 2100 2520 3480 4140 4800