35
12.3. DISASSEMBLE OF SELECT-
ABLE COMPARTMENT
Remove ice compartment (IC) door and selectable compart-
ment (SC) door with case.
12.3.1. PCB of PF
1. Remove the ice compartment (IC) door and selectable
compartment (SC) door with case.
2. Remove screw for UV lamp cover.
3. Remove PCB of PF.
4. Disconnect connector.
12.3.2. SENSOR SCC
1. Remove the selectable compartment (SC) door and case.
2. Remove SC sensor cover
Remove the screw for SC sencor cover. Then remove SC
sensor cover inserting the screw driver (-) under the hook
in the figure.
3. The wire harness remove from fixed hook, and remove
SC sensor from SC sensor cover.
Caution
1. Cut the wire harenss of Sensor SCC at near the Sensor
SCC body.
2. Cut the wire harness of new sensor SCC in a appropriate
length, then connect the wire harenss by the schotch
lock.
12.4. DISASSEMBLY OF VC AND FC
COMPARTMENT
1. Remove VC door and FC door.
a. Fully open the VC door and FC door, then take out VC
case and FC case.
b. Unscrew screws (2 pieces) of support frame Assy L
and R.
c. Lifting the door a little and pulls it toward front side.
Then unhook from interior part of Rail Assy L and R.