94
Subject: Panasonic projector report(CONFIGURE)
=== Panasonic projector report(CONFIGURE) ===
Projector Type : D7700
––––– E-mail setup data –––––
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INPUT AIR TEMPERATURE Over [ 35C / 95F ]
ERROR [ON ]
LAMP1 RUNTIME [OFF] at REMAIN [200] H
LAMP1 RUNTIME [OFF] at REMAIN [100] H
LAMP2 RUNTIME [OFF] at REMAIN [200] H
LAMP2 RUNTIME [OFF] at REMAIN [100] H
INPUT AIR TEMPERATURE [OFF]
PERIODIC REPORT
Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ ON ]
Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ]
00:00 [OFF] 01:00 [OFF ] 02:00 [OFF] 03:00 [OFF]
04:00 [OFF] 05:00 [OFF ] 06:00 [OFF] 07:00 [OFF]
08:00 [OFF] 09:00 [OFF ] 10:00 [OFF ] 11:00 [OFF]
12:00 [OFF] 13:00 [OFF] 14:00 [OFF] 15:00 [OFF]
16:00 [OFF] 17:00 [OFF] 18:00 [ON ] 19:00 [OFF ]
20:00 [OFF] 21:00 [OFF] 22:00 [OFF] 23:00 [OFF]
––––– check system –––––
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
OUTPUT AIR TEMPERATURE [ OK ]
LAMP2 REMAIN TIME [ OK ]
LAMP1 REMAIN TIME [ OK ]
Contents of mail sent
Mail with the contents shown below is sent when the E-mail settings have been established.
Subject: Panasonic projector report(ERROR)
=== Panasonic projector report(ERROR) ===
Projector Type : D7700
––––– check system –––––
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
OUTPUT AIR TEMPERATURE [ OK ]
LAMP2 REMAIN TIME [ OK ]
LAMP1 REMAIN TIME [ OK ]
LAMP2 STATUS [ OK ]
LAMP1 STATUS [ FAILED ]
OPTICS MODULE TEMP.SENSOR [ OK ]
INPUT AIR TEMP.SENSOR [ OK ]
OUTPUT AIR TEMP.SENSOR [ OK ]
BATTERY [ OK ]
(Error code 00 40 00 00)
Input air temperature : 27 degC / 80 degF
Output air temperature : 65 degC /149 degF
SET RUNTIME 1857 H
POWER ON 248 times
LAMP1 ON 177 times
LAMP1 LOW 0 H
LAMP1 HIGH 68 H
LAMP2 ON 183 times
LAMP2 LOW 0 H
LAMP2 HIGH 75 H
LAMP1 REMAIN 1432 H
LAMP2 REMAIN 1425 H
––––– Network configuration –––––
IP address 192.168.0.8
MAC address 00:00:00:00:00:00
Wed Jan 26 18:54:31 2005