Chapter 7Appendix — Technical information
ENGLISH - 251
Class
Command
Control details
Parameter/response
string
Remark
2 IRES ?
Input signal resolution
query
AAAAxBBBB
AAAA: Horizontal resolution
BBBB: Vertical resolution
2 RRES ?
Recommended
resolution query
1920 x 1200 Returns display resolution.
2 FILT ? Filter runtime inquiry xxxxx Returns the runtime of the lter.
2 RFIL ?
Filter replacement
model number inquiry
ET-RFM100 Returns the lter replacement model number.
2
FREZ Freeze control 0 Freeze clear
FREZ ? Freeze status query 1 Freeze (stop)
2 POWR
Cooling notication 0 Noties when the power is turned o󰀨.
Warmup notication 1 Noties when the power is turned on.
2 ERST Error notication xxxxxx Noties when an error occurs.
2 LKUP Link up notication xx:xx:xx:xx:xx:xx
Noties the MAC address when the PJLink communication
becomes possible.
2 INPT
Input switch
completion notication
31 HDMI1
32 HDMI2
33 DIGITAL LINK
34 SDI
2 SRCH Projector search
ACKN=xx:xx:xx:xx:xx:xx
The projector connected to the same network that can
communicate with PJLink will respond with its MAC address.
PJLink security authentication
A PJLink password for security authentication procedure is required for communication of the PJLink command.
The PJLink password can be set in the [NETWORK] menu [PJLink] [PJLink PASSWORD] (x page 173), or
in “[Set up password] page (when accessed by administrator account)” (x page 210) of the web control screen.
When communicating the PJLink command without authentication procedure, set the PJLink password as blank.
The factory default setting of the PJLink password is blank.
f For specications related to PJLink, visit the website of Japan Business Machine and Information System
Industries Association.
URL http://pjlink.jbmia.or.jp/english/
Using Art-Net function
Since the network function of the projector supports the Art-Net function, you can control the projector settings
with the DMX controller and application software using the Art-Net protocol.
Note
f To use the Art-Net function with the projector, it is necessary to set the password of the administrator account. (x page 169)
f The Art-Net function cannot be used using the “IPv6” protocol. Set the [NETWORK] menu [WIRED LAN] [IP VERSION] to either [IPv4]
or [IPv4 & IPv6] and assign the IP address for “IPv4”.
Channel denition
The following table lists the channel denitions used for controlling the projector with the Art-Net function.
Channel settings can be switched using the [NETWORK] menu [Art-Net] [Art-Net CHANNEL SETTING]
(x page 175).
The control details assigned to each channel are listed in the following table.
f Channel assignment for [USER] is in factory default setting. Assignment can be changed.
Channel
Control details
[2] [USER] [1]
CHANNEL1 LIGHT OUTPUT LIGHT OUTPUT SHUTTER
CHANNEL2 INPUT SELECT INPUT SELECT INPUT SELECT
CHANNEL3 LENS POSITION LENS POSITION LENS FUNCTION SELECT
CHANNEL4 LENS H SHIFT LENS H SHIFT LENS CONTROL
CHANNEL5 LENS V SHIFT LENS V SHIFT POWER
CHANNEL6 LENS FOCUS LENS FOCUS LIGHT OUTPUT
CHANNEL7 LENS ZOOM LENS ZOOM ENABLE/DISABLE
CHANNEL8 POWER POWER FADE-IN