Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
Value
1: Enable - Used Reversed FLDINV
Setting Value
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
1:Enable (Service Adjustment
Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable
(Dzoom is not cancelled even if
Keystone is cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9
Sensivity for Signal Lost
(HSYNC)
Only used this value for No Signal
Judgement(Hz)
350 0 - 32767
10
Sensivity for Signal Lost
(VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value Reference Value 16 0 - 30
Group
205
Spread Spetrum
0 Enable 0=Enable, 1=Disable 1 0 - 1
1 Modulation frequency 300 1 - 500
2 Diffusivity 200 0 - 300
Group
210
Lamp Control
0
DIMMER_CTRL_LEVEL_MIN
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the Value
13 0-255
1 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer:
Dim Level 2 at the less than the Value
24 0-255
2 DIMMER_CTRL_LEVEL2
Luminance Level 1 Data for Dimmer:
Dim Level 3 at the less than the Value
35 0-255
3 DIMMER_CTRL_LEVEL3
Luminance Level 1 Data for Dimmer:
Dim Level 4 at the less than the Value
46 0-255
4 DIMMER_CTRL_LEVEL4
Luminance Level 1 Data for Dimmer:
Dim Level 5 at the less than the Value
57 0-255
5 DIMMER_CTRL_LEVEL5
Luminance Level 1 Data for Dimmer:
Dim Level 6 at the less than the Value
69 0-255
6 DIMMER_CTRL_LEVEL6
Luminance Level 1 Data for Dimmer:
Dim Level 7 at the less than the Value
100 0-255
7 DIMMER_CTRL_LEVEL7
Luminance Level 1 Data for Dimmer:
Dim Level 8 at the less than the Value
150 0-255
8
DIMMER_CTRL_LEVEL_MAX
Luminance Level 1 Data for Dimmer:
Dim Level 9 at the less than the Value
200 0-255
11 Cooling Gain Current cooling gain value - 0 - 255 * Read only
12
DIMMER_LEVEL_AUTO_Max
Max Dimmer Level for Lamp
mode=Auto
128 0 - 128
13
DIMMER_LEVEL_AUTO_Min
Min Dimmer Level for Lamp
mode=Auto
38 0 - 128
14 Rate of dimmer level's step
Rate of Dimmer Level for Lamp
mode=Auto
128 0 - 128
15
DIMMER_AVERAGE_POINT
Luminance Data Avarage Point for
Mimmer
2 1 - 16
16 DIMMER_AVERAGE_DATA
Luminance Data Avarage Value for
Dimmer
- 0 - 255 * Read only
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl - 0 - 128 * Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level 128 0 - 128
19 DIMMER_LEVEL_ECO Eco Dimmer Level 89 0 - 128
20 Lamp check enable 0 0 - 1
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
21 VOLTAGE_LEVEL Lamp Voltage - Unit: 8bit(Raw Data) * Read only
22 DIMMER_LEVEL_HIGH Dimmer level High 71 0 - 128
Group
230
VBI Slice Level
0 Generic Initial Slicing Level PW190 register 0xE344 40 0-255
1
Generic High Level Threshold
PW190 register 0xE345
-
0-255
* Read only
2
Generic Low Level Threshold
PW190 register 0xE346
-
0-255
* Read only
3
Generic Minimum Low Level
PW190 register 0xE347 40 0-255
4 Generic Maximum High Level PW190 register 0xE348 200 0-255