-50-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group
250
FAN Control * Fan volltage adjustment
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
18 0-255
1 FAN1 MAX ADJUST (DAC) 207 0-255
2 FAN2 MIN ADJUST (DAC) 45 0-255
3 FAN2 MAX ADJUST (DAC) 207 0-255
4 FAN3 MIN ADJUST (DAC) 94 0-255
5 FAN3 MAX ADJUST (DAC) 194 0-255
Group
252
FAN Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land "On1", 2: Hi-
Land "On2"
- 0 - 2
* Read only
1 SAFETY SWITCH For test purpose 0 0,3-6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100 0-255
4 FAN2 MANUAL VOLTAGE 100 0-255
5 FAN3 MANUAL VOLTAGE 100 0-255
Group
253
Fan Tem Error Setting (Memorized) Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0 Temp A Warning (High) 9999 -
1 Temp B Warning (High) 9999 -
2 Temp C Warning (High) 9999 -
3 Temp B-A Warning(High) 9999 -
4 Temp C-A Warning(High) 9999 -
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
39 39 36/36 36/36 30-127
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
52 52 51/52 51/52 30-127
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
73 73 69/70 69/70 30-127
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100
100/100 100/100
0-127
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100
100/100 100/100
0-127
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
39 39 36/36 36/36 30-127
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
52 52 50/52 50/52 30-127
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
70 70 65/68 65/68 30-127
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100
100/100 100/100
0-127
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100
100/100 100/100
0-127
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
5 0-127
16
Temp B Warning Offset
(Temp)
5 0-127
17
Temp C Warning Offset
(Temp)
10 0-127
18
Temp B-A Warning Offset
(Temp)
0 0-127
19
Temp C-A Warning Offset
(Temp)
0 0-127
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-5
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
Group
254
Fan Control Range Setting (Temp./Voltage) Normal Ceiling
HiLand-
Normal
ON1/
ON2
HiLand-
Ceiling
ON1/
ON2
0 High Fan Control Min Temp 9999 -
1 High Fan Control Max Temp 9999 -
2 High Fan1 Min 9999 -
3 High Fan1 Max 9999 -
4 High Fan2 Min 9999 -